Clyde Building
Inspections
★★★★★ 4.8 on Google · 570+ reviews

Frame inspection in Clyde

The frame is the last look at structure. Once sarking, cladding and plaster go on, bracing and tie-down cannot be checked without opening the wall.

  • Once the frame and roof trusses are up, before sarking and cladding
  • 1 to 2 hours on site
  • Report within 24 hours
Get your Clyde inspection priceTakes about a minute. No obligation.

Fully licensed & accredited

Stage3 of 7
When to bookOnce the frame and roof trusses are up, before sarking and cladding
Time on site1 to 2 hours on site
Inspected againstAS 1684 (timber framing), AS 4100 or NASH for steel frames, the engineer's bracing and tie-down plan, NCC Part 3.4

What is included in a Clyde frame inspection

  • Stud, plate, lintel and beam sizes against AS 1684 and the engineer's drawings
  • Wall straightness and plumb, top plate level
  • Floor level across the slab
  • Bracing type, position and fixing against the bracing plan
  • Tie-downs from roof to wall and wall to slab
  • Triple grips, straps and bolt fixings
  • Jack studs, lintels and trimmers over every opening
  • Window sill trimmers for wide openings
  • Roof truss spacing, fixing and girder connections
  • Valley boards, ceiling battens and roof bracing
  • Window and door openings against the plans
  • Wet area framing, noggings and service penetrations
  • Damaged, split, notched or over-drilled members
  • Termite collars and slab penetrations still visible
Why it matters here

Frame inspections on Clyde builds

Casey is an N2 wind area under AS 4055, which sets how much bracing and tie-down the frame needs. That is the number the fixings on your site have to satisfy.

What we find at this stage in Clyde

  • Bottom plate fixings outside 600mm nail or 1200mm bolt centres
  • Walls out of plumb beyond tolerance
  • Stud and plate nailing below the minimum
  • Bracing not extended and bent as required
  • Termite physical barrier not installed
  • Patio and porch post fixings inadequate
Stud to plate fixing below the minimum required, Clyde
Stud to plate fixing below the minimum required
Roof bracing not extended and bent as the standard requires, Clyde
Roof bracing not extended and bent as the standard requires
Sample findings

Sample defects found during our frame inspections in Clyde

Annotated findings from Frame inspections on Clyde builds. Client addresses withheld.

Wall framing out of plumb beyond the allowed tolerance, found during a frame inspection in Clyde
Wall framing out of plumb beyond the allowed tolerance
Bottom plate not fixed to the slab at the required spacing, found during a frame inspection in Clyde
Bottom plate not fixed to the slab at the required spacing
Termite physical barrier not installed under the external walls, found during a frame inspection in Clyde
Termite physical barrier not installed under the external walls
Patio and porch post fixings inadequate for the structural load, found during a frame inspection in Clyde
Patio and porch post fixings inadequate for the structural load

The other stages of a Clyde build

  1. Bored piers inspection in Clyde1Bored piersAfter the holes are bored and steel cages are placed, before concrete
  2. Slab pre-pour inspection in Clyde2Slab pre-pourThe day before the pour, while steel and pods are still open to view
  3. Lock-up (pre-plaster) inspection in Clyde4Lock-up (pre-plaster)After cladding, roof and external doors, before plaster goes on
  4. Fixing inspection in Clyde5FixingOnce skirtings, architraves, doors and joinery are in, before painting
  5. Waterproofing inspection in Clyde6WaterproofingAfter the membrane is applied, before any tile is laid over it
  6. Pre-handover (PCI) inspection in Clyde7Pre-handover (PCI)Before you sign at practical completion, ideally a week ahead

All construction stage inspections in Clyde →

Guides

Construction stage guides for Clyde

All guides →

Book a frame inspection in Clyde

Instant online pricing, or talk to the booking team on 1300 471 805.

FAQ

Frame inspections in Clyde: common questions

Why is frame the most important stage?

It is the last point where structure is visible. Everything after it is covering up.

What does N2 mean for my frame?

N2 is the wind classification for this area. It drives how much bracing is required and how the frame is tied down to the slab. We check the fixings against it.

Do you check the trusses?

We check what is visible and how they are fixed and braced. The truss design itself is certified by the fabricator.

What if the builder disagrees?

Each finding cites the clause or the spacing required, so the discussion is about the number, not opinion.

What standard applies?

AS 1684 for timber framing and AS 4055 for wind classification.

Can the frame be inspected after plaster?

No, which is the whole point of attending at this stage.

CallGet a Free Quote